Skip to main content

MasterLine 10

Technical information

Performance

Energy

Thermal insulation - Uf
0.99 W/m²K
Thermal insulation - Uw
0.8 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer, @1.23x1.48m (104mm sight line), 48mm glass

Comfort

Acoustics - Rw(C;Ctr)
TuTi: 46(-1;-4) dB DC: 44(-2;-4) dB

Safety

Burglar resistance
RC2,RC5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Sightlines

Min. frame width (inward opening)
2 3/8 inch
Min. vent width (inward opening)
1 7/16 inch
Min. frame-vent width (inward opening)
4 1/8 inch
Min. frame width (outward opening)
1 1/16 inch
Min. vent width (outward opening)
4 7/16 inch
Min. frame-vent width (outward opening)
5 1/2 inch
Depth frame
3 13/16 inch
Depth Vent
4 3/16 inch
Depth frame-vent
4 3/16 inch

Glazing

Rebate height
1 1/16 inch
Min. glass thickness - vent
1 3/16 inch
Max. glass thickness - vent
3 7/16 inch