Skip to main content

ConceptWall 60

Technical information

Performance

Comfort

Air tightness
AE 1950 (1950Pa)
Water tightness
RE1950 (1950Pa)
Wind load resistance
E2400 (2400Pa)

Safety

Burglar resistance
RC2 - RC3
Impact resistance
I5/E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Max. weight of glass
1653 lbs
Min. intertia mullion - Ix
45 cm4
Max. intertia mullion - Ix
1940 cm4
Min. intertia transom - Ix
45 cm4
Max. intertia transom - Ix
871 cm4
Min. intertia transom - Iy (glass load)
33 cm4
Max. intertia transom - Iy (glass load)
111 cm4

Sightlines

Min. width T-profile
2 3/8 inch
Min. visible width (interior view)
2 3/8 inch
Min. visible width (exterior view)
2 3/8 inch
Min. depth mullion
2 7/16 inch
Max. depth mullion
9 7/8 inch
Min. depth transom
2 5/8 inch
Max. depth transom
8 7/16 inch

Glazing

Glazing method
Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing
Min. glass thickness - frame/element
1/4 inch
Max. glass thickness - frame/element
2 3/8 inch