ConceptWall 60 Opening Elements
Technical informationPerformance
Energy
- Thermal insulation - Uw Double
- 0.23 Btu/hr.ft².°F
- Thermal insulation - Uw Triple
- 0.14 Btu/hr.ft².°F
Comfort
- CWCT tested according to
- Sequence B
- Air Leakage CWCT
- A4 (600Pa)
- Water Penetration CWCT
- R7 (600Pa)
- Wind Resistance (Serviceability) CWCT
- 2400 Pa
- Wind Resistance (Safety) CWCT
- 3600 Pa
- Acoustics STC
- 41 dB
Properties
Sightlines
- Min. width T-profile
- 2 3/8 inch
Glazing
- Glazing method
- Dry glazing - External glazing - Glazing bead - Structural Glued Glazing - Structural Glued Stepped Glazing