ConceptWall 60 Mullion Transom
Technical informationPerformance
Comfort
- Air tightness
- Class 4 (600Pa)
- Water tightness
- RE1200 (1200 Pa)
- Wind load resistance
- E2400 (2400Pa)
Safety
- Burglar resistance
- RC2 - RC3
- Impact resistance
- I5/E5
Properties
Max. dimensions & weight
- Min. height of vent
- 23 5/8 inch
- Min. width of vent
- 17 11/16 inch
- Max. weight of vent
- 396 lbs
Sightlines
- Min. width T-profile
- 2 3/8 inch
- Min. visible width (interior view)
- 2 3/8 inch
- Min. visible width (exterior view)
- 2 3/8 inch
Glazing
- Rebate height
- 1 inch
- Glazing method
- Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing
- Min. glass thickness - frame/element
- 7/8 inch
- Max. glass thickness - frame/element
- 2 7/16 inch